IMADA specializes in
force measurement

MENU

Product Search

Solution Search

FAVORITES

Roller Grip

GC-60/100

  1. Force Measurement IMADA
  2. PRODUCTS
  3. Tension Attachments
  4. GC-60/100

Description Add to favorites

GC-60 GC-60

Stretch Sample

Single Touch

Fix by Winding

Self-Tightening

Lo-Mid Force

GC-60/100 is roller grip with 500N capacity. It reduces sample slippage and breaking as the sample is winded around the grip. It is ideal for measurement of extensible sample such as rubber, film, tape, etc.

Feature

  • Ideal for measurement of extensible sample such as rubber, film, tape, etc.
  • Reduces sample slippage and breaking as the sample is winded around the grip
  • Performs measurement accurately and easily due to its self-tightening mechanism

Relevant Industrial Standards

IEC 60286-3 [ 2022 ] [Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes] (corresponding part only)

JIS C 0806-3 [ 2021 ] [Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes] (corresponding part only)

Example of Product Configuration

GC-60(4)

GC-60

1G2005A
1G2005B
1G2005C
1G2005D
Configuration for rupture test of cover tape film1G2005A

Features

This testing system is designed for rupture test of embossed carrier tape's cover film.

It complies with the corresponding part of JIS C0806-3 (2021).

Winding clamp method reduces breaking samples, and holds samples well.

inquiry number

1G2005A

Present the “inquiry number” below when you contact us, for prompt assistance.

Relevant Industrial Standards

IEC 60286-3 [ 2022 ] [Packaging of components for automatic handling - Part 3: Packaging of surface mount components on continuous tapes] (corresponding part only)

JIS C0806-3 [ 2021 ] [Packaging of surface mount components on continuous tapes] (Corresponding part only)

Cautions

Refer to specifications of each product for details.
Product configuration varies depending on the shape and characteristic of the sample, and measurement conditions.
The recommended capacity of measurement instruments varies depending on the expected force to be loaded.

Add to favorites
CONTACT
Configuration 1 for tensile test using GC-60.1G2005B

Features

GC-60 is designed to grip elastic or deformable samples such as rubber, film, and the like.

This testing system offers a simple solution of tensile test up to 500N.

Winding clamp method reduces breaking samples, and holds samples well.

inquiry number

1G2005B

Present the “inquiry number” below when you contact us, for prompt assistance.

1g2005a.webp

Add to favorites
CONTACT
Cautions

Extensible samples require longer stroke, therefore, you need to check if a test stand has long stroke enough for your sample.
Refer to specifications of each product for details.
Product configuration varies depending on the shape and characteristic of the sample, and measurement conditions.
The recommended capacity of measurement instruments varies depending on the expected force to be loaded.

Add to favorites
CONTACT
Configuration 2 for tensile test using GC-60.1G2005C

Features

GC-60 is designed to grip elastic or deformable samples such as rubber, film, and the like.

This testing system offers a functional & versatile solution of tensile test up to 500N.

Winding clamp method reduces breaking samples, and holds samples well.

inquiry number

1G2005C

Present the “inquiry number” below when you contact us, for prompt assistance.

Cautions

Extensible samples require longer stroke, therefore, you need to check if a test stand has long stroke enough for your sample.
Refer to specifications of each product for details.
Product configuration varies depending on the shape and characteristic of the sample, and measurement conditions.
The recommended capacity of measurement instruments varies depending on the expected force to be loaded.

Add to favorites
CONTACT
Configuration 3 for tensile test using GC-60.1G2005D

Features

GC-60 is designed to grip elastic or deformable samples such as rubber, film, and the like.

This testing system enables you to evaluate characteristics by force-displacement measurement.

The capacity is 500N.

Winding clamp method reduces breaking samples, and holds samples well.

inquiry number

1G2005D

Present the “inquiry number” below when you contact us, for prompt assistance.

1g2005d.webp

Add to favorites
CONTACT
Product used

Force Displacement Analysis Unit

FSA-0.5K2-500N-L

1

Optional Attachment

GC-60

2

Cautions

Extensible samples require longer stroke, therefore, you need to check if a test stand has long stroke enough for your sample.
A test sample is deformed when it is winded, which influences the results of displacement measurement.
Refer to specifications of each product for details.
Product configuration varies depending on the shape and characteristic of the sample, and measurement conditions.
The recommended capacity of measurement instruments varies depending on the expected force to be loaded.

Add to favorites
CONTACT
Unit
Converter
Unit Converter

Convenient Unit/Torque/
Tension conversion

6 Significant Digits (*Significant digits are meaningful digits that do not include zeros, which are used to indicate the scale.)

Products

CLICK
HERE!
Attachments, Grips & Fixtures Attachments, Grips & Fixtures
Custom Made Custom Made